{"title":"12 \/ 24 Volt DC Centrifugal Pumps","description":"\u003cp\u003eOur 12 \/ 24 Volt DC Centrifugal Pumps products are selected for pressure washing, fluid transfer, spraying and industrial equipment applications. \u003c\/p\u003e\n\u003cp\u003eBrowse our 12 \/ 24 Volt DC Centrifugal Pumps range below with fast UK delivery available. \u003c\/p\u003e\n\u003c!-- __pwsuk_auto_collection__ --\u003e","products":[{"product_id":"50840-2012-jabsco-12vdc-lp-cyclone-pump","title":"Jabsco 12VDC LP Cyclone Pump","description":"\u003cul\u003e\n \u003cli\u003e0.6 Bar max pressure\u003c\/li\u003e\n \u003cli\u003e120 Lpm max flow\u003c\/li\u003e\n \u003cli\u003eNon self-priming\u003c\/li\u003e\n \u003cli\u003e12 Volt DC 9 Amp electric motor\u003c\/li\u003e\n \u003cli\u003eAISI316 stainless steel head\u003c\/li\u003e\n \u003cli\u003eNitrile seals\u003c\/li\u003e\n \u003cli\u003eAnti-clog impeller\u003c\/li\u003e\n \u003cli\u003ePrimes up to 2m when wet\u003c\/li\u003e\n \u003cli\u003eContinuously rated\u003c\/li\u003e\n \u003cli\u003e3\/4\"BSP female ports\u003c\/li\u003e\n \u003cli\u003e4 to 95°C fluid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eJabsco Cyclone general purpose centrifugal pumps are engineered using 316 stainless steel and are ideal for engine cooling, closed-circuit circulation systems, LiveWell circulation, central heating, chemical transfer, calf feeding carts, dairy milk transfer, and other flooded suction applications.\u003c\/p\u003e\n\u003cp\u003eThe Jabsco Cyclone pumps offer brushed motors capable of 2,500-3,500 hours along with an anti-clog impeller that allows small debris to pass through the pump. If servicing or adjustment is necessary, only a 3\/8\" spanner is needed to remove the impeller to inspect the mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe Cyclone series of pumps can also handle seawater, fresh water, anti-freeze, mild chemicals, and bilge water, milk, and accepts fluid temperatures between 4ºC and 95ºC.\u003c\/p\u003e\u003cbr\u003e \u003cdiv class=\"divider divider-AalRmcGlyWjJHaHRCN__divider_VJhene spacing-style\" style=\" --divider-justify-content: center; --padding-block-start: 0px;--padding-block-end: 0px; \"\u003e \u003cspan class=\"divider__line\" style=\" --divider-border-thickness: 1px; --divider-border-rounded: 0; --divider-flex-basis: 100%; \"\u003e\u003c\/span\u003e \u003c\/div\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"pdfLinks pdfLinks3\"\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Flojet\/FLJ%2050840%20TECH%20DATA.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Flojet\/FLJ 50840 TECH DATA.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"50840 Cyclone Technical Information (opens in new window)\"\u003e50840 Cyclone Technical Information\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Flojet\/FLJ%20CYCLONE%20SERIES%20OVERVIEW%20AND%20APPLICATIONS.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Flojet\/FLJ CYCLONE SERIES OVERVIEW AND APPLICATIONS.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"Range Overview \u0026amp; Applications (opens in new window)\"\u003eRange Overview \u0026amp; Applications\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User%20Manuals\/Flojet\/FLJ%2050840%20SERIES%20USER%20MANUAL.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User Manuals\/Flojet\/FLJ 50840 SERIES USER MANUAL.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"Cyclone 50840 Series User Manual (opens in new window)\"\u003eCyclone 50840 Series User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":57160956805455,"sku":"50840-2012","price":322.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/7930\/5039\/files\/download_21ebae9c-582c-4bee-adb9-18675d0d18c9.jpg?v=1774305831"},{"product_id":"50840-2024-jabsco-24vdc-lp-cyclone-pump","title":"Jabsco 24VDC LP Cyclone Pump","description":"\u003cul\u003e\n \u003cli\u003e0.6 Bar max pressure\u003c\/li\u003e\n \u003cli\u003e120 Lpm max flow\u003c\/li\u003e\n \u003cli\u003eNon self-priming\u003c\/li\u003e\n \u003cli\u003e24 Volt DC 4.5 Amp electric motor\u003c\/li\u003e\n \u003cli\u003eAISI316 stainless steel head\u003c\/li\u003e\n \u003cli\u003eNitrile seals\u003c\/li\u003e\n \u003cli\u003eAnti-clog impeller\u003c\/li\u003e\n \u003cli\u003ePrimes up to 2m when wet\u003c\/li\u003e\n \u003cli\u003eContinuously rated\u003c\/li\u003e\n \u003cli\u003e3\/4\"BSP female ports\u003c\/li\u003e\n \u003cli\u003e4 to 95°C fluid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eJabsco Cyclone general purpose centrifugal pumps are engineered using 316 stainless steel and are ideal for engine cooling, closed-circuit circulation systems, LiveWell circulation, central heating, chemical transfer, calf feeding carts, dairy milk transfer, and other flooded suction applications.\u003c\/p\u003e\n\u003cp\u003eThe Jabsco Cyclone pumps offer brushed motors capable of 2,500-3,500 hours along with an anti-clog impeller that allows small debris to pass through the pump. If servicing or adjustment is necessary, only a 3\/8\" spanner is needed to remove the impeller to inspect the mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe Cyclone series of pumps can also handle seawater, fresh water, anti-freeze, mild chemicals, and bilge water, milk, and accepts fluid temperatures between 4ºC and 95ºC.\u003c\/p\u003e\u003cbr\u003e \u003cdiv class=\"divider divider-AalRmcGlyWjJHaHRCN__divider_VJhene spacing-style\" style=\" --divider-justify-content: center; --padding-block-start: 0px;--padding-block-end: 0px; \"\u003e \u003cspan class=\"divider__line\" style=\" --divider-border-thickness: 1px; --divider-border-rounded: 0; --divider-flex-basis: 100%; \"\u003e\u003c\/span\u003e \u003c\/div\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"pdfLinks pdfLinks3\"\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Flojet\/FLJ%2050840%20TECH%20DATA.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Flojet\/FLJ 50840 TECH DATA.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"50840 Cyclone Technical Information (opens in new window)\"\u003e50840 Cyclone Technical Information\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Flojet\/FLJ%20CYCLONE%20SERIES%20OVERVIEW%20AND%20APPLICATIONS.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Flojet\/FLJ CYCLONE SERIES OVERVIEW AND APPLICATIONS.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"Range Overview \u0026amp; Applications (opens in new window)\"\u003eRange Overview \u0026amp; Applications\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User%20Manuals\/Flojet\/FLJ%2050840%20SERIES%20USER%20MANUAL.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User Manuals\/Flojet\/FLJ 50840 SERIES USER MANUAL.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"Cyclone 50840 Series User Manual (opens in new window)\"\u003eCyclone 50840 Series User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":57160957034831,"sku":"50840-2024","price":322.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/7930\/5039\/files\/download_5586c1ef-a6c3-4129-9c03-74e958c536ad.jpg?v=1774305832"},{"product_id":"50860-2012-jabsco-12vdc-hp-cyclone-pump","title":"Jabsco 12VDC HP Cyclone Pump","description":"\u003cul\u003e\n \u003cli\u003e1.3 Bar max pressure\u003c\/li\u003e\n \u003cli\u003e80 Lpm max flow\u003c\/li\u003e\n \u003cli\u003eNon self-priming\u003c\/li\u003e\n \u003cli\u003e12 Volt DC 21 Amp electric motor\u003c\/li\u003e\n \u003cli\u003eAISI316 stainless steel head\u003c\/li\u003e\n \u003cli\u003eNitrile seals\u003c\/li\u003e\n \u003cli\u003eAnti-clog impeller\u003c\/li\u003e\n \u003cli\u003ePrimes up to 2m when wet\u003c\/li\u003e\n \u003cli\u003eIntermittent rated\u003c\/li\u003e\n \u003cli\u003e3\/4\"BSP female ports\u003c\/li\u003e\n \u003cli\u003e4 to 95°C fluid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eJabsco Cyclone general purpose centrifugal pumps are engineered using 316 stainless steel and are ideal for engine cooling, closed-circuit circulation systems, LiveWell circulation, central heating, chemical transfer, calf feeding carts, dairy milk transfer, and other flooded suction applications.\u003c\/p\u003e\n\u003cp\u003eThe Jabsco Cyclone pumps offer brushed motors capable of 2,500-3,500 hours along with an anti-clog impeller that allows small debris to pass through the pump. If servicing or adjustment is necessary, only a 3\/8\" spanner is needed to remove the impeller to inspect the mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe Cyclone series of pumps can also handle seawater, fresh water, anti-freeze, mild chemicals, and bilge water, milk, and accepts fluid temperatures between 4ºC and 95ºC.\u003c\/p\u003e\u003cbr\u003e \u003cdiv class=\"divider divider-AalRmcGlyWjJHaHRCN__divider_VJhene spacing-style\" style=\" --divider-justify-content: center; --padding-block-start: 0px;--padding-block-end: 0px; \"\u003e \u003cspan class=\"divider__line\" style=\" --divider-border-thickness: 1px; --divider-border-rounded: 0; --divider-flex-basis: 100%; \"\u003e\u003c\/span\u003e \u003c\/div\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"pdfLinks pdfLinks3\"\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Flojet\/FLJ%2050860%20TECH%20DATA.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Flojet\/FLJ 50860 TECH DATA.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"50860 Cyclone Technical Information (opens in new window)\"\u003e50860 Cyclone Technical Information\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Flojet\/FLJ%20CYCLONE%20SERIES%20OVERVIEW%20AND%20APPLICATIONS.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Flojet\/FLJ CYCLONE SERIES OVERVIEW AND APPLICATIONS.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"Range Overview \u0026amp; Applications (opens in new window)\"\u003eRange Overview \u0026amp; Applications\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User%20Manuals\/Flojet\/FLJ%2050860%20SERIES%20USER%20MANUAL.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User Manuals\/Flojet\/FLJ 50860 SERIES USER MANUAL.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"Cyclone 50860 Series User Manual (opens in new window)\"\u003eCyclone 50860 Series User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":57160957067599,"sku":"50860-2012","price":360.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/7930\/5039\/files\/download_03f8c1c4-9773-4211-9fea-8d63cba4e635.jpg?v=1774305831"},{"product_id":"50860-2024-jabsco-24vdc-hp-cyclone-pump","title":"Jabsco 24VDC HP Cyclone Pump","description":"\u003cul\u003e\n \u003cli\u003e1.3 Bar max pressure\u003c\/li\u003e\n \u003cli\u003e80 Lpm max flow\u003c\/li\u003e\n \u003cli\u003eNon self-priming\u003c\/li\u003e\n \u003cli\u003e24 Volt DC 10.5 Amp electric motor\u003c\/li\u003e\n \u003cli\u003eAISI316 stainless steel head\u003c\/li\u003e\n \u003cli\u003eNitrile seals\u003c\/li\u003e\n \u003cli\u003eAnti-clog impeller\u003c\/li\u003e\n \u003cli\u003ePrimes up to 2m when wet\u003c\/li\u003e\n \u003cli\u003eIntermittent rated\u003c\/li\u003e\n \u003cli\u003e3\/4\"BSP female ports\u003c\/li\u003e\n \u003cli\u003e4 to 95°C fluid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eJabsco Cyclone general purpose centrifugal pumps are engineered using 316 stainless steel and are ideal for engine cooling, closed-circuit circulation systems, LiveWell circulation, central heating, chemical transfer, calf feeding carts, dairy milk transfer, and other flooded suction applications.\u003c\/p\u003e\n\u003cp\u003eThe Jabsco Cyclone pumps offer brushed motors capable of 2,500-3,500 hours along with an anti-clog impeller that allows small debris to pass through the pump. If servicing or adjustment is necessary, only a 3\/8\" spanner is needed to remove the impeller to inspect the mechanical seal.\u003c\/p\u003e\n\u003cp\u003eThe Cyclone series of pumps can also handle seawater, fresh water, anti-freeze, mild chemicals, and bilge water, milk, and accepts fluid temperatures between 4ºC and 95ºC.\u003c\/p\u003e\u003cbr\u003e \u003cdiv class=\"divider divider-AalRmcGlyWjJHaHRCN__divider_VJhene spacing-style\" style=\" --divider-justify-content: center; --padding-block-start: 0px;--padding-block-end: 0px; \"\u003e \u003cspan class=\"divider__line\" style=\" --divider-border-thickness: 1px; --divider-border-rounded: 0; --divider-flex-basis: 100%; \"\u003e\u003c\/span\u003e \u003c\/div\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n","brand":"My Store","offers":[{"title":"Default Title","offer_id":57160957100367,"sku":"50860-2024","price":360.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/7930\/5039\/files\/download_94c95e3c-0df0-4e44-9cd3-097f38649832.jpg?v=1774305831"},{"product_id":"9700b-hypro-12vdc-aqua-tiger-pump","title":"Hypro 12VDC Aqua Tiger Pump","description":"\u003cul\u003e\n \u003cli\u003e0.48 Bar max pressure\u003c\/li\u003e\n \u003cli\u003e72 Lpm max flow\u003c\/li\u003e\n \u003cli\u003eNon self-priming\u003c\/li\u003e\n \u003cli\u003e12 Volt DC 11 Amp electric motor\u003c\/li\u003e\n \u003cli\u003eBronze impeller \u0026amp; head\u003c\/li\u003e\n \u003cli\u003eViton lip seal \u0026amp; O rings\u003c\/li\u003e\n \u003cli\u003e3\/4\"NPT female ports\u003c\/li\u003e\n \u003cli\u003e60°C max fluid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e \u003cdiv class=\"divider divider-AalRmcGlyWjJHaHRCN__divider_VJhene spacing-style\" style=\" --divider-justify-content: center; --padding-block-start: 0px;--padding-block-end: 0px; \"\u003e \u003cspan class=\"divider__line\" style=\" --divider-border-thickness: 1px; --divider-border-rounded: 0; --divider-flex-basis: 100%; \"\u003e\u003c\/span\u003e \u003c\/div\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"pdfLinks pdfLinks3\"\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Parts%20Lists%20(pdf)\/Hypro\/HYP%209700%20PARTS%20LIST.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Parts Lists (pdf)\/Hypro\/HYP 9700 PARTS LIST.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"9700 Series Parts List (opens in new window)\"\u003e9700 Series Parts List\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Hypro\/HYP%209700%20TECH%20DATA.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Hypro\/HYP 9700 TECH DATA.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"9700 Series Technical Information (opens in new window)\"\u003e9700 Series Technical Information\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User%20Manuals\/Hypro\/HYP%209700%20USER%20MANUAL.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User Manuals\/Hypro\/HYP 9700 USER MANUAL.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"9700 Series User Manual (opens in new window)\"\u003e9700 Series User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":57168213344591,"sku":"9700B","price":451.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/7930\/5039\/files\/download_4582eeb0-13ce-4d60-8454-5811e2c8e463.jpg?v=1774305006"},{"product_id":"9700s-hypro-12vdc-aqua-tiger-pump","title":"Hypro 12VDC Aqua Tiger Pump","description":"\u003cul\u003e\n \u003cli\u003e0.48 Bar max pressure\u003c\/li\u003e\n \u003cli\u003e72 Lpm max flow\u003c\/li\u003e\n \u003cli\u003eNon self-priming\u003c\/li\u003e\n \u003cli\u003e12 Volt DC 11 Amp electric motor\u003c\/li\u003e\n \u003cli\u003eAISI 316 st.steel impeller \u0026amp; head\u003c\/li\u003e\n \u003cli\u003eViton lip seal \u0026amp; O rings\u003c\/li\u003e\n \u003cli\u003e3\/4\"NPT female ports\u003c\/li\u003e\n \u003cli\u003e60°C max fluid temperature\u003c\/li\u003e\n\u003c\/ul\u003e\u003cbr\u003e \u003cdiv class=\"divider divider-AalRmcGlyWjJHaHRCN__divider_VJhene spacing-style\" style=\" --divider-justify-content: center; --padding-block-start: 0px;--padding-block-end: 0px; \"\u003e \u003cspan class=\"divider__line\" style=\" --divider-border-thickness: 1px; --divider-border-rounded: 0; --divider-flex-basis: 100%; \"\u003e\u003c\/span\u003e \u003c\/div\u003e \u003cbr\u003e\u003cp\u003e\u003c\/p\u003e\n\u003cul class=\"pdfLinks pdfLinks3\"\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Parts%20Lists%20(pdf)\/Hypro\/HYP%209700%20PARTS%20LIST.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Parts Lists (pdf)\/Hypro\/HYP 9700 PARTS LIST.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"9700 Series Parts List (opens in new window)\"\u003e9700 Series Parts List\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical%20Data\/Hypro\/HYP%209700%20TECH%20DATA.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/Technical Data\/Hypro\/HYP 9700 TECH DATA.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"9700 Series Technical Information (opens in new window)\"\u003e9700 Series Technical Information\u003c\/a\u003e\u003c\/p\u003e\n \u003cp\u003e\u003ca href=\"https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User%20Manuals\/Hypro\/HYP%209700%20USER%20MANUAL.pdf\" target=\"_blank\" onclick=\"javascript:window.open('https:\/\/www.dualpumps.co.uk\/files\/pdf\/products\/User Manuals\/Hypro\/HYP 9700 USER MANUAL.pdf','_blank','width=800,height=600,resizable=yes,scrollbars=yes,menubar=yes,location=yes,toolbar=yes'); return false;\" title=\"9700 Series User Manual (opens in new window)\"\u003e9700 Series User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":57168213377359,"sku":"9700S","price":423.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1000\/7930\/5039\/files\/download_309d1d0e-0ef4-4a3e-afb0-061fd26c8f66.jpg?v=1774305005"}],"url":"https:\/\/www.pressurewashingsuppliesuk.co.uk\/collections\/12-24-volt-dc-centrifugal-pumps.oembed","provider":"Pressure Washing Supplies UK","version":"1.0","type":"link"}